Fluke Ti300 Infrared Camera

Fluke Electronic

Fluke authorised distributor and calibration house.

The Fluke Ti300 comes complete with LaserSharp® Auto Focus and a rugged design, built to last in any environment.

More details

4335314

New

Delivery TBC

£ 4,695.00

(£ 5,634.00 inc VAT.)

Add to wishlist

Take focus to the extreme - Get the Ti450, Ti400, Ti300 or Ti200 thermal imager and a FREE lens*.

Purchase the Ti450, Ti400, Ti300 or Ti200 Thermal Imager and get your choice of a free telephoto or wide angle smart lens. Offer valid between May 16th, 2017 and December 31, 2017. Fluke smart lenses do not require calibration.

*This promotion is not available to customers outside EU28, Switzerland and Norway.

The Fluke Ti300 thermal camera is equipped with LaserSharp Auto Focus for perfectly focused images. Every thermal camera user knows that focus is the single most important thing to ensure when conducting an infrared inspection.

Without an in-focus image temperature measurements may not be accurate, sometimes by as much as 20 degrees, so it's much easier to miss a problem. LaserSharp Auto Focus tells you exactly where you are focusing. It uses a laser to calculate the distance to your target before it focuses. Place the red laser dot on the equipment you are inspecting, then pull and release the trigger for a perfect in-focus image.

All thermal imagers need sufficient warm-up time for the most accurate temperature measurements and best image quality. This time can often vary by model and by environmental conditions.

Although most imagers are fully warmed up in 3-5 minutes, it is always best to wait a minimum of 10 minutes if the most accurate temperature measurement is important to your application. When you move the Imager between environments with large differences in ambient temperature, more adjustment time can be required.

FEATURES

Faster communication with wireless image transfer.
Fluke Connect App - See It. Save It. Share It. All the facts, right in the field.
More advanced display output options.
Voice recording and annotation.
Rechargeable, field replaceable smart batteries with LED display.
5 MP industrial-performance digital camera.
Included SmartView and SmartView Mobile App Analysis and Reporting Software.

FLUKE Ti300 TECHNICAL SPECIFICATIONS
IFOV (spatial resolution) 1.75 mRad
Detector resolution 240x180 (43,200 pixels)
Field of view 24 °H x 17 °V
Minimum focus distance 15 cm (approx. 6 in)
Optional lenses Telephoto lens, wide angle lens
Focus system LaserSharp® Auto Focus for consistently in-focus images, manual focus
Laser distance meter Yes
Wireless connectivity Fluke Connect® app compatible. Wireless connectivity to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN1
IR-Fusion® technology IR-Fusion® AutoBlend™ mode and Picture-in-Picture
Display Touchscreen capacitive 3.5 inch diagonal landscape color VGA (640 x 480) LCD with backlight
Design Rugged, ergonomic design for one-handed use
Thermal sensitivity (NETD) ≤ 0.05 °C at 30 °C target temp (50 mK)
Temperature measurement range -20 °C to +650 °C (-4 °F to+1202 °F)
Built-in digital camera (visible light) 5 megapixel industrial performance
Frame rate 60 Hz or 9 Hz versions
Data Storage and Image Capture
Extensive memory options Removable micro SD memory card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection
File formats image Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2)
No analysis software required for non-radiometric (.bmp, .jpg and .avi) files
SmartView® software SmartView® software, Fluke Connect®1, and SmartView® Mobile App—full analysis and reporting software
Voice annotation 60 seconds maximum recording time per image; reviewable playback on camera
IR-PhotoNotes™ Yes
Video recording Standard and radiometric
Streaming video (remote display) Via USB or WiFi hot spot to PC or via HDMI to HDMI compatible screen
Auto capture (temperature and interval) Yes
Battery
Batteries (field-replaceable, rechargeable) Two lithium ion smart battery packs with five-segment LED display to show charge level
AC battery charging system Two-bay battery charger or in imager charging. Optional 12 V automotive charging adapter
Temperature Measurement
Accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
On-screen emissivity correction Yes (both value and table)
On-screen reflected background temperature compensation Yes
On-screen transmission correction Yes
General Specifications
Color palettes 8 standard and 8 Ultra Contrast™: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
Color alarms (temperature alarms) High-temperature, low-temperature, and isotherm
Spot temp Hot and cold spot markers
User-definable spot markers 3 user definable spot markers on camera and in SmartView® software
Center box Expandable-contractible measurement box with MIN-MAX-AVG temp
Drop Engineered to withstand 2 meter (6.5 feet) drop with standard lens
Size (H x W x L) 27.7 cm x 12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in)
Weight (battery included) 1.04 Kg (2.3 lb)
Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Warranty Two-years (standard), extended warranties are available
Includes: Ti300 Thermal camera with standard infrared lens, AC power supply and battery pack charger (including mains adapters), Two, rugged lithium ion smart battery packs, USB cable, HDMI video cable, SmartView® software available via free download, Rugged, hard carrying case, Soft transport bag, Adjustable hand strap, Warranty registration card, International adapter set (9 Hz only).

Fluke Ti300 VIDEO

Screen (Total Pixels) 43,200
Temp. Range -20 °C to +650 °C (-4 °F to+1202 °F)
Focus LaserSharp Auto Focus for consistently in-focus images, manual focus
IR Resolution 240 x 180 pixels
Thermal Sensitivity ≤ 0.05 °C at 30 °C target temp (50 mK)