Fluke 717-300G Pressure Calibrator
Includes: Fluke 717-300g, Protective Yellow Holster with test lead storage, Instructions Sheet (14 languages), single 9V alkaline battery, Test Leads and Alligator Clips, NIST-traceable calibration report and data.
The Fluke 717-300g Pressure Calibrator delivers outstanding performance, durability and reliability. The calibrator is compact, lightweight, and easy to carry. With a push button interface similar to the multifunction Fluke 750 Series Documenting Process Calibrators, the Fluke 717 Pressure Calibrator is easy to use.
It is EMI tolerant, dust and splash resistant, and features a removable battery door for quick battery changes. The Fluke 717 Pressure Calibrator is compatible with Fluke 700Pxx differential, gauge and absolute pressure modules to increase functionality.
FEATURES:
Measure pressure, 0.05% of full scale with internal sensor.
Measure mA with 0.015% accuracy and 0.001 mA resolution, while sourcing 24 V loop power
Measure pressure to 10,000 psi/700 bar using one of 29 Fluke 700Pxx Pressure Modules.
1/8 NPT female pressure fitting.
Compatible with non-corrosive Gases and liquids.
Select eleven different engineering units.
Zero, min, max, and hold functions.
Calibrate P/I instruments with simultaneous pressure and current measurement.
Pressure switch test function captures set, reset and Deadband values of a pressure switch.
Error % calculation of mA measurements for quick pass-fail decisions.
Long lasting battery life.
Holster features test lead storage.
Compatible with Toolpack magnetic hanging system.
New switch test.
Measurement Accuracy | ||
Pressure | Fluke 717 Series | |
Measure Pressure | (Internal sensor). | |
Accuracy | 0.05% full scale. | |
Functions | Zero, min, max, hold, damp. | |
Note gasses / liquids (non-corrosive). | ||
Fluke 717 1G | ||
Range | -1 to 1 psi, (-68.9 mbar to 68.9 mbar, -83 to 6.89 kPa). | |
Resolution | 0.0001 psi, 0.001 mbar, 0.0001 kPa. | |
Over pressure | 5 x full scale. | |
Fluke 717 30G | ||
Range | -12 to 30 psi, (-850 mbar to 2 bar, -83 to 206.84 kPa). | |
Resolution | 0.001 psi, 0.1 mbar, 0.01 kPa. | |
Over Pressure | 2 x full scale. | |
Fluke 717 100G | ||
Range | -12 to 100 psi, (-850 mbar to 7 bar, -83 to 689.48 kPa). | |
Resolution | 0.01 psi, 0.1 mbar, 0.01 kPa. | |
Over pressure | 2 x full scale. | |
Fluke 717 300G | ||
Range | -12 to 300 psi, (-850 mbar to 20 bar, -83 to 2068.42 kPa). | |
Resolution | 0.01 psi, 1 mbar, 0.1 kPa. | |
Over pressure | 375 psi, 25 bar. | |
Fluke 717 500G | ||
Range | 0 to 500 psi, (0 mbar to 34,7 bar, 0 to 3447.38 kPa). | |
Resolution | 0.01 psi, 1 mbar, 0.1 kPa. | |
Over pressure | 2 x full scale. | |
Fluke 717 1000G | ||
Range | 0 to 1000 psi, (0 mbar to 69 bar, 0 to 6894.76 kPa). | |
Resolution | 0.1 psi, 1 mbar, 0.1 kPa. | |
Over pressure | 2 x full scale. | |
Fluke 717 1500G | ||
Range | 0 to 1500 psi, (0 bar to 103.4 bar, 0 to 10342 kPa). | |
Resolution | 0.1 psi, 0.01 mbar, 1 kPa. | |
Over pressure | 2 x full scale. | |
Fluke 717 3000G | ||
Range | 0 to 3000 psi, (0 bar to 207 bar, 0 to 20684.27 kPa). | |
Resolution | 0.1 psi, 0.01 bar, 1 kPa. | |
Over pressure | 2 x full scale. | |
Fluke 717 5000G | ||
Range | 0 to 5000 psi, (0 bar to 345 bar, 0 to 34474 kPa). | |
Resolution | 0.1 psi, 0.01 bar, 1 kPa. | |
Over pressure | 2 x full scale. | |
Fluke 717 Series with Pressure Modules | ||
Measure pressure | (Via pressure module connector using optional Pressure Modules). | |
Range | 29 pressure modules, 0-1 inH20 to 10,000 psi, 2.5 mbar to 700 bar ranges. Over pressure per pressure module specs. | |
Resolution | Per pressure module specs. | |
Accuracy | Per pressure module specs. | |
Functions | Zero, min, max, hold, damp. | |
Current | Range | 0 to 24 mA (-25% to 125%). |
Resolution | 0.001 mA. | |
Accuracy | 0.015% + 2 counts. | |
Specifications | ||
Loop power | Range | 24 V DC. |
Accuracy | ±10%. | |
Drive; 20 mA into 1000 ohms for battery > 6.8 V; 700 W for battery 5.8 to 6.8 V. | ||
Display | Clear 5 digit LCD. | |
Environmental Specifications | ||
Operating temperature | -10°C to 55°C. | |
Storage temperature | -40°C to 60°C. | |
Humidity (without condensation) | 95% (10°C to 30°C). | |
75% (30°C to 40°C). | ||
45% (40°C to 50°C). | ||
35% (50°C to 55°C). | ||
Operating altitude | 3,000 M max. | |
Safety Specifications | ||
Safety | CSA C22.2 No. 1010.11992. | |
Mechanical and General Specifications | ||
Size (L x W x H) | 201 x 98 x 52 mm (7.93 x 3.86 x 2.06 in). | |
Weight | 22 oz, approximately 600 G with holster. | |
Fluke 717 warranty | 3 years. | |
Shock and vibration | Random, 2 G, 5-500 Hz. | |
1 m drop test. | ||
Battery type | Single 9 V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline. |
No customer reviews for the moment.
COMPONENT |
DESCRIPTION | PART No. | ||
C90 | Soft meter case. | 466029 | ||
C25 | The C25 carrying case is a durable, zippered carrying case with padding and inside pocket, and high quality polyester exterior. | 1281997 | ||
AC220 | SureGrip™ Alligator Clip Set. | 1610103 | ||
AC258 | SureGrip Aligator Clips. | 1610159 | ||
700PRV-1 | Fluke 700PRV Pressure Relief Valve Kit. | 2811808 | ||
700HTH-1 | The Fluke 700HTH-1 hydraulic test hose allows connection to both a Fluke pressure module and a calibration unit under test from a Fluke 700HTP-1 hydraulic test pump simultaneously. | 2811795 | ||
700PMP | Hand-operated pressure pump to provide pressures up to 150 psi/1000 kPa. | 617131 | ||
700HTP-2 | Hydraulic test pump, 690 bar. | 4096855 | ||
TL220-1 | SureGrip™ Industrial Test Lead Set designed to provide a reliable grip in slippery hands. With interchangeable test lead set for multiple electrical applications. | 3971178 | ||
TL71-1 | The TL71-1 Premium Test Lead Set has one pair of red and black comfort grip probes with flexible silicone-insulated, right-angle test leads.. | 3971207 |