- Hamilton01698 829711
- Leeds0113 235 1356
- Belfast02890 830302
Fluke 9100S Handheld Dry-Well
Includes: Power Cord, Fluke 9100S Dry-Well User's Guide with Report of Calibration, RS-232 Cable, 9930 Interface-it Software and User's Guide.
The Fluke 9100S Mid-Range Field Calibrator may be used as a portable instrument or bench top temperature calibrator for calibrating thermocouple and RTD temperature probes. This instrument is small enough to use in the field, and accurate enough to use in the lab. Calibrations may be done over a range of 35°C to 375°C (95°F to 707°F). Temperature display and setability resolution is 0.1 degrees.
Plug it in, switch it on set the temperature with the front-panel buttons, and insert your probe into the properly sized well. Compare the reading of your device to the display temperature or to an external reference, and the difference is the error in your device. With a proprietary Fluke Calibration temperature controller, the 9100S has a display resolution of 0.1 degrees, an accuracy of ±0.5°C, a stability of ±0.1°C, and a stabilization time of just five minutes.
The temperature is accurately controlled by Fluke’s digital controller. The controller uses a precision platinum RTD as a sensor and controls the well temperature with a triac driven heater.
The LED front panel continuously shows the current well temperature. The temperature may be set, using the control buttons, to any desired temperature within the instrument’s range. Multiple fault protection devices insure user and instrument safety and protection.
FEATURES
Rapid heating and cooling.
Prop stand.
RS-232 interface capability.
Temperature scan rate control.
Eight set-point memory.
Adjustable readout in °C or °F.
Range | 35 °C to 375 °C (95 °F to 707 °F. |
Accuracy | ± 0.25 °C at 50 °C; ± 0.25 °C at 100 °C; ± 0.5 °C at 375 °C. |
Stability | ± 0.07 °C at 50 °C; ± 0.1 °C at 100 °C; ± 0.3 °C at 375 °C. |
Well-to-Well Uniformity | ± 0.2 °C with sensors of similar size at equal depths within wells. |
Heating times | 35 °C to 375 °C: 9.5 minutes. |
Stabilisation | 5 minutes. |
Cooling times | 375 °C to 100 °C: 14 minutes. |
Well depth | 102 mm (4 in);1.6 mm (1/16 in) hole is 89 mm (3.5 in) deep. |
Removable inserts | N/A |
Power | 115 V ac (± 10 %), 55–65 Hz, 1.5 A or 230 V ac (± 10 %), 0.8 A, 45–55 Hz, 175 W. |
Computer interface | RS-232 interface. |
Dimensions | 57 x 125 x 150 mm (2.25 x 4.9 x 6.1 in). |
Weight | 1 kg (2 lb 3 oz). |
Fluke 9100S warranty | 1 year. |
No customer reviews for the moment.
COMPONENT PARTS | DESCRIPTION | PART No. | |
Insert | AL 1/2" X 4" blank. | 3102-0 | |
Insert | AL 1/2" X 4" 1/16". | 3102-1 | |
Insert | AL 1/2" X 4" 1/8". | 3102-2 | |
Insert | AL 1/2" X 4" 3/16". | 3102-3 | |
Insert | AL 1/2" X 4" 1/4". | 3102-4 | |
Insert | AL 1/2" X 4" 5/16". | 3102-5 | |
Insert | AL 1/2" X 4" 3/8". | 3102-6 | |
Insert | AL 1/2" X 4" 7/16". | 3102-7 | |
Insert | AL 1/2" X 4" 5/32". | 3102-8 | |
Case | Rugged Carrying Case: 9100S. | 9300 |