- Hamilton01698 829711
- Leeds0113 235 1356
- Belfast02890 830302
Megger AVO410 Digital Multimeter
Includes: Megger AVO410 digital multimeter, test leads and probes.
The Megger AVO410 is aimed at providing electricians with a rugged, easy to use multimeter for field use. Functions include voltage, current and resistance; in addition, there are extra functions that may also appeal to electrical and electronic engineers. The instrument features automatic or manual selection of ranges, True RMS readings and a CATIV 600 V safety rating.
The slim, compact case has a tough rubberised holster that provides that extra degree of protection from the extreme conditions found in industrial environments. The style of the AVO410 case and positioning of the function switch and buttons means the unit sits comfortably in the palm for single handed use.
FEATURES
6000 count backlit digital display.
True RMS reading on AC mode.
1000 V DC / 750 V AC ranges.
10 A AC / DC ranges.
Resistance, frequency and capacitance ranges.
CAT IV 600 V.
AC/DC Voltage | ||
---|---|---|
Range | DC Accuracy | AC Accuracy |
600.0mV | ±0.5% + 2 digits | 50 Hz/60 Hz sine wave for 600.0 mV range, ± (0.9% + 5 digits) 50 to 500 Hz *1 |
6.000V | ||
60.00V | ||
600V | ||
DC 1000V / AC 750V | ||
Overvoltage Protection | DC 1000 V or AC. | |
Input Impedance | 10 MΩ // less than 100 pF. | |
CMRR (Common Mode Rejection Ratio/Normal Mode Rejection Ratio) | VAC: CMRR>60 dB at DC, 50 Hz/60 Hz. | |
VDC: CMRR > 10 dB at DC, 50/60 Hz. | ||
NMRR: >50 dB at DC, 50/60 Hz. | ||
AC Conversion Type | AC conversions are AC courple True RMS responding, calibrated to the sine wave input. | |
Note: *1 The basic accuracy is specified for a sine wave below 4000 counts. Over 4000 counts, add 0.6% to the accuracy. For non-sine waves below 2000 counts, refer to the following for accuracy: ±1.5% addition error for C.F from 1.4 to 3. | ||
Crest Factor | C.F = peak/rms. | |
AC/DC Current | ||
Range | DC Accuracy | AC Accuracy |
600.0 μA | ±(1.0% + 2 digits) | N/A. |
6000 μA | ||
6.000 A | ±(1.5% + 6 dgt) 50Hz - 500Hz *1 | |
10.00 A | ||
Overload Protection | A Input: 10 A (500 V) fast blow fuse. | |
μA Input: 600 V rms. | ||
*1 AC Conversion Type: Conversion type and additional specification are the same AC/DC voltage. | ||
Resistance | ||
Range | Accuracy | Overload Protection |
600.0 Ω * 2 | ±(0.7% + 2 digits) | 600V rms. |
6.000 kΩ | ||
60.00 kΩ | ||
600.0 kΩ | ||
6.000 MΩ | ±(1.0% + 2 digits) | |
60.00 MΩ * 1 | ±(1.5% + 2 digits) | |
*1 Less than 20 Hz, the sensitivity is 1.5 V rms. | ||
*2 Max sensitivity <5 V AC rms. | ||
Capacitance | ||
Range | Accuracy | |
6.000 nF | ±(1.9%) + 8 digits. | |
60.00 nF | ||
600.0 nF | ||
6.000 μF | ||
60.00 μF | ||
600.0 μF | ||
6.00 mF*3 | ||
Overload Protection | 600 V rms. | |
*3 <100 digit of reading rolling. | ||
General Specifications | ||
Display | 6000 counts, updates 1.5/sec. | |
Polarity Indication | Automatic, positive implied, negative indicated. | |
Overrange Indication | "OL" or "-OL". | |
Low Battery Indication | Displayed when the battery voltage drops below operating voltage. | |
Auto Power Off | Approx 10 minutes. | |
Operating Conditions | Non-condensing ≤10 °C, 11 °C ~ 30 °C (≤80% R.H) 31 °C ~ 40 °C (≤75% R.H), 41 °C ~ 50 °C (≤45% R.H). |
|
Storage Temperature | -20 to 60°C, 0 to 80% RH when battery removed from meter. | |
Temperature Coefficient | 0.15 x (Spec.Acc'y) / °C, <18°C or >28°C. | |
Safety | IEC 61010 CAT IV 600 V. | |
Power Requirements | Standard 9 V battery: PP3, NEDA 1604, IEC6422 or JIS006P. | |
Battery Life | Alkaline: 300 hours. | |
Dimensions (W x H x D) | 76 x 158 x 38 mm without holster. | |
82 x 164 x 44 mm with holster. | ||
Weight | 522g. | |
Megger AVO410 warranty | One-year (3 years upon registration). |
No customer reviews for the moment.
COMPONENT PARTS | DESCRIPTION | PART No. | ||
Lead Set | Test lead set - comprising 2 unfused leads (red/black). Short prods and croc clips. Boxed. | 1002-001B | ||
Fused Lead Set | Fused test lead set. Red/black, FF500 mA. Boxed. | 1002-015B | ||
Pouch | Pouch for AVO210/410. | 2007-366 |