T&R PT18-10 mk2
  • T&R PT18-10 mk2
  • T&R PT18-10 mk2 DC Cable Test Systems
  • T&R PT18-10 mk2
  • T&R PT18-10 mk2

T&R PT18-10 mk3 DC Cable Test Systems

T&R Approved distributor and service company.

Includes: 2m long supply lead, Spare 7A fuse, 2 x 5m long output leads, DP20 discharge probe, PT18-10 Mk2 Operating manual.

063
£10181.00
£12217.2 Inc. VAT

The T&R PT18-10 high voltage dc test set is designed to perform tests on installed cable and jointing systems. The units have a variable output voltage with a maximum of ±18kVdc with a maximum charging capability of 10mA. A zero-volt interlock is fitted that prevents the output being switched on unless the output control is at zero.

In the event of a test object failure, the overload circuit will automatically switch off the output voltage and earth the output via the internal discharge circuit. A manual discharge probe is also supplied as standard with the T&R PT18-10 mk3 unit, allowing higher load capacitances to be safely discharged.

The mk3 units introduce automatic 115/230V mains voltage selection, allowing easy transition between site voltages.

FEATURES

±18kVdc output voltage.
10mA output capability.
Both voltage and current metered on HV outputs.
Automatic earth system for dumping capacitive loads.
HV output plug & socket system.
Key operated supply switch to prevent unauthorised operation.
Zero-volt interlock.
Visual indication of test piece failure.
Automatic mains voltage selection.

T&R PT18-10 Mk3 Specifications
Output
Unit Type Voltage Continuous 5 Minutes
PT18-10 0 to ±18 kV. 5 mA. 10 mA.
The above intermittent on times must be followed by an off time of 15 minutes and is based on ambient temperature of 25° C.
Metering
The positive and negative output voltages on the PT series are metered on the HV output by separate analogue instruments.
Unit Range Accuracy
PT18-10 0 to 20 kV. ±1.5% of full scale.
The output current on both of the outputs is metered by a dual range analogue instrument. The 1 mA range is selected by the 10 pushbutton adjacent to the mA meter.
Unit Range Accuracy
PT18-10 10 mA.
1 mA.
±2.5% of full scale.
1 mA ±2.5% of full scale.
Overload Protection
The PT18-10 mk3 is protected by an overload trip on the output that operates at 12mA.
Supply Requirements 115V/230 V±10% auto-selecting
50/60 Hz 1ph 600 VA max.
Protection and safety
The output of the unit is protected by an overload trip, and the input and control supplies are protected by fuses.
General
Storage temperature -20° C to 60° C.
Operating temperature 0°C to 45° C.
Dimensions 471 x 144 x 362 mm.
Weight 17 kg unit only.
25 kg including bag & leads.
T&R PT18-10 mk2 warranty 1 year.

Download

T&R PT30-10 & 18-10 Datasheet

PDF Specifications of the T&R Pt18-10 & PT30-10 mk2 high voltage dc test sets.

Download (1.75M)

No customer reviews for the moment.

Write your review

T&R PT18-10 mk3 DC Cable Test Systems
COMPONENT
DESCRIPTIONPART No.
10m Leads10m HV leads.A063-193
10m Earth10m earth lead.A064-112
15m Leads15m HV leads.A063-172
15m Earth15m earth lead.A064-101
20m Leads20m HV leads.A064-156
20m Earth20m earth lead.A064-157
DP20DP20 discharge probe, carry case including space for leads.066