Fluke 54 Series II Dual Input Digital Thermometer
Includes: Fluke 54 Series II, Impact absorbing holster, 2x 80-PK-1 bead probe thermocouple and user manual.
The Fluke Model 54 Thermometer is a microprocessor-based, digital thermometer designed to use external J-, K-, T-, E-, R-, S-, and N-type thermocouples (temperature probes) as temperature sensors.
The Fluke 54 II features Min / max / avg with relative time clock and an electronic offset function allowing compensation of thermocouple errors to maximise overall accuracy.
FEATURES
Relative time clock on MIN, MAX, and AVG provides a time reference for major events.
Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy.
Measures J, K, T, and E-types of thermocouples.
Additional thermocouple types R, S, and N (for a total of 7 different types).
Recall function allows logged data to be easily reviewed on the meter display.
Infrared USB communication port allows data to be exported to optional FlukeView Forms.
Data Logging up to 500 points of data with user adjustable recording interval.
Readout in ºC, ºF, or Kelvin (K).
Large backlit dual display.
Splash and dust resistant case protected by impact absorbing holster.
User-friendly front panel is easy to set up and operate.
Sleep mode increases battery life; typical 1000-hour battery life.
Battery door allows easy battery replacement without breaking the calibration seal.
Optional ToolPak accessory.
Temperature accuracy | Above -100°C | J, K, T, E, and N-type: ±[0.05% + 0.3°C]1 |
R and S-type: ±[0.05% + 0.4°C]1 | ||
Below -100°C | J, K, E, and N-types: ±[0.20% + 0.3°C]1 | |
T-type: ±[0.50% + 0.3°C] | ||
Temperature | J-type | -210°C to 1200°C |
K-type | -200°C to 1372°C | |
T-type | -250°C to 400°C | |
E-type | -150°C to 1000°C | |
N-type | -200°C to 1300°C1 | |
R and S-type | 0°C to 1767°C1 | |
Temperature scale | ITS-90. | |
Applicable standards | NIST-175. | |
Display resolution | 0.1°C, 0.1 K < 1000. | |
1°C, 1 K ≥ 1000. | ||
1. Only the Fluke Models 53 II B and 54 II B thermometers are capable of measuring N, R, and S-type thermocouples. | ||
Environmental Specifications | ||
Operating temperature | -10°C to 50°C. | |
Storage temperature | -40°C to 60°C. | |
Humidity (without condensation) | 0% to 90%; 0°C to 35°C. | |
0% to 70%; 0°C to 50°C. | ||
Safety Specifications | ||
Overvoltage category | CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2. | |
Agency approvals | CE, CSA, TÜV (pending). | |
Mechanical and General Specifications | ||
Dimensions (L x W x D) | 173 x 86 x 38 mm. | |
Weight | 400 g. | |
Batteries | 3 AA batteries; typical 1000-hour life. | |
Fluke 54 Series II warranty | 3 years. |
No customer reviews for the moment.
COMPONENT PARTS | DESCRIPTION | PART No. | |
C50 | Zippered carrying case with inside pocket belt loop and inside meter. | 762823 | |
C550 | Tool Bag. | 1547919 | |
CXT170 | Extreme case. Unbreakable, watertight, airtight, dustproof, chemical resistant and corrosion proof. | 3352567 | |
TPAK | ToolPak™ Magnetic Meter Hanger Kit includes: 9 inch hook and loop strap Universal hanger clip Hook hanger for non magnetic surfaces Strong magnet. |
1281997 | |
80PK-1 | Type-K thermocouple for general purpose applications. | 750422 | |
80PK-22 | Fluke 80PK-22 SureGrip™ Immersion Temperature Probe is designed for use in liquid and gels. | 2098684 | |
80PK-24 | Type-K thermocouple for use in air and non-caustic gas measurements. | 2098691 | |
80PK-25 | SureGrip™ Piercing Temperature Probe. | 2098706 | |
80PK-8 | The Fluke 80PK-8 Pipe Clamp Temperature Probe uses Type-K thermocouple for fast temperature and superheat measurements of pipe surfaces. | 200360 |