Fluke V3001 FC Wireless DC Voltage Module
Includes: v3001 Voltage Module, TL222 Test Leads, AC220 Alligator Clips, Magnetic hanging strap.
Connect the v3001 FC wireless DC voltage module, or any of the other Fluke Connect remote modules, and read the results on the Fluke Connect Wireless Multimeter or a portable PC from a safe distance.
The Fluke v3001 FC Wireless DC Voltage Module is fully functional DC voltage meter that wirelessly relays DC voltage measurements to other Fluke Connect enabled master units including; Fluke 3000 FC DMM, Fluke Ti200/300/400 Infrared Camera, PC via optional pc3000 FC Adapter and the Fluke Connect Mobile app.
FEATURES
Use as a standalone meter or as part of the system.
Use the logging function for recording and saving up to 65,000 readings.
Fluke V3001 Specifications
Voltage Specifications | ||
Function | ||
mV DC | Range¹ / resolution | 600.0 mV / 0.1 mV. |
Accuracy | 0.09% + 3. | |
VDC | Range¹ / resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V. |
Accuracy | 0.09% + 3. | |
Range¹ / resolution | 1000 V / 1 V. | |
Accuracy | 0.15% + 2. | |
Accuracy is specified for 1 year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading] + [Number of least significant digits]).All ranges are autoranging. Accuracy is specified from the range obtained by autoranging, from 18°C to 28°C. | ||
General Specifications | ||
LCD w/backlight | 3½ digits, 6000 counts, updates 4/sec. | |
Battery type | 2 AA, NEDA 15 A, IEC LR6. | |
Battery life | 400 Hours. | |
Memory | Record up to 65000 readings. | |
RF communications | 2.4 GHZ ISM Band. | |
RF communication range | Open air, unobstructed | Up to 20 m. |
Obstructed, sheetrock wall | Up to 6.5 m. | |
Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m. | |
Operating temperature | -10°C to +50°C. | |
Storage temperature | -40°C to +60°C. | |
Temperature coefficient | 0.1 X (specified accuracy)/°C (< 18°C or > 28°C). | |
Operating humidity | 90% at 35°C, 45% at 40°C, 45% at 50°C. | |
Altitude | Operating | 2,000 m. |
Storage | 12,000 m. | |
EMC | EN 61326–1:2006. | |
Safety compliance | ANSI/ISA 61010–1 / (82.02.01) | 3rd edition. |
CAN / CSA–C22.2 No 61010–1–12 | 3rd edition. | |
UL 61010–1 | 3rd edition. | |
IEC/EN 61010–1 | 2010. | |
Safety rating | CAT IV 600 V, CAT III 1000 V. | |
Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE. | |
Ingress Protection (IP) rating | IP42. | |
Pollution Degree | 2. | |
Dimensions (H x W x D) | 160 x 66 x 38 mm (6.3 x 2.6 x 1.5 in). | |
Weight | .255 kg (9 oz). | |
Fluke V3001 warranty | Three years. | |
Note: Not compatible with Fluke CNX test tools. |