- Hamilton01698 829711
- Leeds0113 235 1356
- Belfast02890 830302
Megger Egil with PC
Megger Egil with PC has a USB port for communication with a PC and the CABA Win™ Circuit Breaker Analysis Software.
The Megger Egil with PC comes with a USB interface for communication with a PC and the CABA Win™ Circuit Breaker Analysis Software.
The Egil is intended for use on circuit breakers with one contact per phase. EGIL incorporates features commonly found on more complex test systems, but is designed to be smaller, simpler to use and less expensive than other similar test sets. If the main contacts are equipped with parallel pre-insertion resistor contacts, the Megger Egil automatically records the difference between main and resistor contacts. Auxiliary contact timing as well as coil current traces are recorded.
The Megger EGIL is equipped with a connector marked USB. The EGIL can be connected to a computer in which the CABA Breaker Analysis program has been installed. This enables you to: store settings and test parameters for individual breakers in the computer; make quick evaluations and comparisons; print out reports; store test results in the computer.
It’s price makes it attractive to smaller utilities and it is an ideal supplementary product for maintenance departments at larger power companies and for testing contractors.
The EGIL is intended primarily for testing high-voltage circuit breakers at medium-level voltages. There must not, however, be more than one break per phase since the time channels are not galvanically isolated. Contact times are recorded for main contacts, pre-insertion resistor contacts and auxiliary contacts. Coil currents are also recorded.
Coil currents are measured automatically and presented together with other readings immediately after testing on the display window or via the built-in printer. EGIL is easy to use – a built-in sequencer (program unit) sets the instrument automatically for the next sequential breaker operation.
Intended primarily for measuring travel (motion), the optional analog input channel finds many other uses as well. If this channel is not installed, all associated menu commands are hidden. A Megger EGIL with the SDRM option together with the SDRM accessory enables static and dynamic resistance measurements.
FEATURES
Suitable for testing timing and travel on all circuit breakers with single interrupter per phase.
Extremely easy-to-use and reliable.
Two separate timing channels for measurement of auxiliary contacts.
Analog measurement channels for travel transducers or general voltage/current measurements.
Static and dynamic resistance measurements along with the SDRM201 optional accessory.
Environment | |||
Application field | For use in medium and high-voltage substations and industrial environments. | ||
Operating temperature | -10°C to +50°C (14°F to +122°F). | ||
Storage | -40°C to +70°C (-40°F to +158°F). |
||
Humidity | 5% – 95% RH, non-condensing. |
||
CE-Marking | |||
LVD | 2006/95/EC. | ||
EMC | 2004/108/EC. | ||
General Specifications | |||
Mains voltage | 115/230 V AC (switchable), 50/60 Hz. | ||
Display | LED. | ||
Mains voltage | 115/230 V AC (switchable), 50/60 Hz. | ||
Power consumption | 100 VA (max). | ||
Time measurement | Measurement time: 1 to 100 s Resolution: 0.1 to 10 ms. |
||
Number of channels | 3 with common ground. | ||
Time base inaccuracy | 0.05% of the reading ± resolution. | ||
Status thresholds | Closed: < 10 Ω ± 20% Resistor: 10 Ω ± 20% to 3 kΩ ±20% Open: > 3 kΩ ± 20%. |
||
Open circuit voltage | 24 V ± 20%. | ||
Short circuit current | 100 mA ± 20%. | ||
AUX 1 & 2 | Number of channels: 2, galvanically isolated. | ||
Contact-sensing (Dry) | Status thresholds | ||
Closed | < 600 Ω ± 30%. | ||
Open | > 600 Ω ± 30%. | ||
Open circuit voltage | 20 V ± 20% DC. | ||
Short circuit current | 25 mA ± 20%. | ||
Voltage sensing (Wet) | Status thresholds | ||
Open indication | < 8 V (polarity insensitive). | ||
Close indication | > 13 V (polarity insensitive). | ||
Working voltage | 250 V AC/DC. | ||
Current measurement | Range: ± 25 A per channel. Resolution: 25 mA. Inaccuracy: 1% of the reading ±100 mA. Working voltage: 250 V AC / DC. |
||
Breaker operation | Sequences: C, O, C-O, O-C, O-C-O. | ||
Continuous current | 5 A. | ||
Max current | 25 A during 300 ms, rest time 1 min. | ||
Contact function | Two independent control functions. | ||
Contact characteristics | Non bouncing, closing time max. 0.1 ms. | ||
Make/Break capacity | 25 A, 250 V (AC or DC) per contact function. | ||
Start breaker operation | By rotary switch. | ||
Pulse length | Adjustable in steps of 10 ms. | ||
Pulse delay | Adjustable in steps of 10 ms. | ||
Working voltage | 250 V AC / DC. | ||
Printout | Type of printout: Graphic and numeric. | ||
Printer | Thermal printer with fixed print head. | ||
Graphic resolution | 8 dots/mm – 203 dpi. | ||
Paper width | 114 mm (4.5”). | ||
Available languages | English, German, French, Spanish, Swedish. | ||
Dimensions | Instrument: 360 x 210 x 190 mm (14.2” x 8.3” x 7.5”) Transport case: 420 x 300 x 230 mm (16.5” x 11.8” x 9.0”). |
||
Weight | 6.3 kg (14 lbs) 10 kg (22 lbs) with accessories and transport case. |
||
Megger Egil warranty | One year. |
No customer reviews for the moment.
COMPONENT |
DESCRIPTION | PART No. | ||
CABA Win |
Circuit breaker analysis software Incl. USB cable. | BL-8206X | ||
SDRM201 | The SDRM201 is intended to use for both static and dynamic resistance measurements (SRM and DRM). | CG-90250 | ||
10M Extension cables | 10 m (33 ft) extension for SDRM201. | GA-12810 | ||
7.5M Extension cables | 7.5 m (24.6 ft) extension for SDRM201. | GA-12815 | ||
VD401 |
Voltage divider, ratio 400/1 (for TM1600 and EGIL with analog channel). | BL-90070 | ||
Thermopaper | 114 mm, 30 m. | GC-00030 |