Chauvin CA6630 Battery Tester
Includes: A set of 2 x 1-m long measurement leads with retractable test probe tips, Data transfer software, C.A 6630 / PC connection cord, Instruction manual in 5 languages.
Ideal for preventive maintenance, the C.A 6630 battery capacity tester fits comfortably in one hand. It is simple to use and allows measurement of the internal resistance and open-circuit voltage. It can test the following types of batteries: Nickel / Cadmium, Lithium-ion , Nickel / metal hybrid, Lead / Acid.
Its double display unit allows simultaneous reading of the internal resistance and of the voltage. For the internal resistance measurement, this tester uses the 4-wire method. This method eliminates the resistance of the measurement cords as a factor and so gives more precise results.
To interpret the result and detect deterioration of a battery rapidly, this tester has 99 reference values (comparator function). The measurement result is thus compared to the theoretical value.
FEATURES
Measurement of internal resistance (4-wire accurate method) and of open circuit voltage (simultaneous display).
Suitable for nickel/cadmium, lithium-ion and nickel/hybrid metal batteries.
Comparator function for rapid assessment of battery deterioration.
Manual storage possible for 999 measurements and continuous data storage (logger mode).
Software for data transfer to a PC and measurement leads supplied.
Resistance | 40 mΩ to 40 Ω. |
Voltage | 4 V to 40 V. |
Automatic standby | 30 minutes of no activity on keys. |
Zero adjustment | Yes (to compensate for the voltage circuit displayed). |
Display | LCD screen with 2 displays and numerous symbols. |
Storage | 999 locations for manual storage and 9600 locations for the automatic storage. |
Power | 6 x 1.5 V batteries – continuous autonomy: 7 hours. |
Maximum power consumed | 1 VA. |
Short-circuit voltage on terminals | 3.5Vpp max. |
Operating conditions | 0°C to +40°C with 80% relative humidity (RH) (no condensation). |
Dimensions | 250 x 100 x 45 mm. |
Weight | 500 g including batteries. |
Chauvin CA.6630 warranty | One-year. |
Download
Chauvin CA6630 Datasheet
PDF Specifications of the Chauvin Arnoux CA6630 Battery Capacity Tester.
Download (477.31k)No customer reviews for the moment.