Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex
Includes: Fluke 376FC, 18-inch iFlex® Flexible Current Probe, TPAK magnetic hanging strap, Soft carrying case, TL75 test leads, Two AA Alkaline batteries, Coated instruction card, Safety information sheet.
The Fluke 376 FC Wireless True-rms AC/DC Clamp Meter offers improved performance perfect for a wide range of current measurement situations. With true-rms voltage and current measurements, the Fluke 376 can read up to 1000 V and 1000 A in both ac and dc modes.
The Fluke Connect® enabled 376 FC Clamp Meter logs measurements to pinpoint intermittent faults precisely without the need for the technician to be present. Those measurements are then wirelessly transmitted to the Fluke Connect app on smartphones or tablets and automatically uploaded to the cloud, keeping technicians outside the arc flash zone and away from dangerous moving machinery, thus improving safety.
Additionally, the Fluke 376 FC includes the iFlex flexible current probe, which expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure around awkward sized conductors and improved wire access. The iFlex probe fits neatly into the bottom of the unit and is an ideal product for bending around conductors that simply aren't possible to test using a conventional clamping system.
FEATURES:
Connect your meter to your smartphone with Fluke Connect Measurements.
Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks.
Record results directly to your phone and the Cloud.
Capture intermittent faults while performing other tasks.
Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls.
iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces.
TPAK magnetic hanging strap.
Integrated VFD low pass filter for accurate motor drive measurements.
Proprietary inrush measurement technology to filter out noise and capture motor starting current.
CAT IV 600 V, CAT III 1000 V safety rating.
Three-year warranty.
AC Current Via Jaws |
|
Range | 999.9 A. |
Resolution | 0.1 A. |
Accuracy | 2% ±5 digits (10 Hz to 100 Hz) 2.5% ±5 digits (100-500 Hz). |
Crest Factor (50/60 Hz) | 3 @ 500 A 2.5 @ 600 A Add 2% for C.F. >2. |
AC Current via Flexible Current Probe |
|
Range | 2500 A. |
Resolution | 0.1 A (≤ 600 A) 1 A (≤ 2500 A). |
Accuracy | 3% ±5 digits (5 – 500 Hz). |
Crest Factor (50/60Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2. |
DC Current |
|
Range | 600.0 A. |
Resolution | 0.1 A. |
Accuracy | 2% ±5 digits. |
AC Voltage |
|
Range | 1000 V. |
Resolution | 0.1 V (≤600.0 V) 1 V (≤1000 V). |
Accuracy | 1.5% ±5 digits (20 Hz to 500 Hz). |
DC Voltage |
|
Range | 1000 V. |
Resolution | 0.1 V (≤600.0 V) 1 V (≤1000 V). |
Accuracy | 1% ±5 digits. |
mV DC |
|
Range | 500.0 mV. |
Resolution | 0.1 mV. |
Accuracy | 1% ±5 digits. |
Frequency Via Jaw | |
Range | 5.0 Hz to 500.0 Hz. |
Resolution | 0.1 Hz. |
Accuracy | 0.5% ±5 digits. |
Trigger Level | 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥5 A 100 Hz to 500 Hz, ≥10 A. |
Frequency via Flexible Current Probe | |
Range | 5.0 Hz to 500.0 Hz. |
Resolution | 0.1 Hz. |
Accuracy | 0.5% ±5 digits. |
Trigger Level | 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz, ≥25 A. |
Resistance |
|
Range | 60 kΩ. |
Resolution | 0.1 Ω (≤600 Ω) 1 Ω (≤6000 Ω) 10 Ω (≤60 kΩ). |
Accuracy | 1% ±5 digits. |
Capacitance |
|
Range | 1000 μF. |
Resolution | 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF). |
Accuracy | 1% ±4 digits. |
Mechanical Specifications | |
Maximum voltage between any terminal and earth ground | 1000 V. |
Batteries | 2 AA, NEDA 15A, IEC LR6. |
Operating Temperature | -10 °C to +50 °C. |
Storage Temp | -40 °C to +60 °C. |
Operating Humidity | Non condensing (< 10 °C) ≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C). |
Operating Altitude | 3000 meters. |
Storage Altitude | 12,000 meters. |
Dimensions | 249 x 85 x 45 mm. |
Weight | 395 g |
Jaw Opening | 34 mm. |
Flexible current probe diameter | 7.5 mm. |
Flexible current probe cable length (head to electronics connector) |
1.8 m. |
Safety | IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V. |
IP Rating | IEC 60529: IP30, non-operating. |
Radio Frequency Certification FCC ID | T68-FBLE IC:6627A-FBLE. |
Fluke 376 FC warranty | 3 years. |
No customer reviews for the moment.
COMPONENT |
DESCRIPTION | PART No. | ||
AC220 | SureGrip™ Alligator Clip Set. | 1610103 | ||
AC87 | Heavy Duty Bus Bar Clip Set. | 1278079 | ||
TP1 | Slim Reach Test Probe (flat blade). | 3971265 | ||
TL75 | Hard Point™ Test Lead Set. | 3971218 | ||
TPAK | ToolPak™ Magnetic Meter Hanger Kit Includes: 9 inch hook and loop strap Universal hanger clip Hook hanger for non magnetic surfaces Strong magnet. |
1281997 | ||
i2500-18 iFlex® | Flexible Current Probes. | 3676405 | ||
i2500-10 iFlex® | Flexible Current Probes. | 3676410 |