Fluke 353 True-rms 2000 A Clamp Meter
  • Fluke 353 True-rms 2000 A Clamp Meter
  • Fluke 353 True-rms 2000 A Clamp Meter
  • Fluke 353 True-rms 2000 A Clamp Meter

Fluke 353 True-rms 2000 A Clamp Meter

Fluke authorised distributor and calibration house.

Includes: Fluke 353 clamp meter, C43 Soft carrying case, 6 AA batteries, User manual.

2840252
£495.00
£594 Inc. VAT
In Stock

Confidently take reliable readings with the True-rms, Fluke 353 digital clamp meter; the tool of choice for high current clamp-on amp meter measurement up to 2000A.

The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.

FEATURES

Reliably handle a wide range of high-current applications with 2000 A AC + DC true-rms, 1400 A ac, and 2000 A DC.
The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors.
CAT IV 600 V, CAT III 1000 V rating for added user protection.
In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability.
Accurately measure frequency up to 1 kHz for optimum troubleshooting.
Quickly analyze readings using the MIN, MAX, and AVG functions.
A large backlit display allows for easy visibility in low-lit areas.
Use the display hold feature to capture readings even when the display cannot be viewed.
Use the low-pass filter to smooth out noisy loads and stabilize readings.

Fluke 353 Specifications
Current measurement DC and AC 10 Hz to 100 Hz Range 40 A / 400 A / 2000 A / 1400 AC RMS.
Resolution 10 mA / 100 mA / 1 A.
Accuracy A: 1.5% rdg + 15 digits
A: 1.5% rdg + 5 digits.
Trigger level for Inrush 0.50 A / 5.0 A / 5 A.
Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A.
Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A.
Crest Factor (50/60 Hz) Range 40 A / 400 A / 2000 A / 1400 AC RMS.
Crest Factor1 2 @ 33 A, 2.4 @ 27 A
2 @ 330 A, 2.4 @ 270 A
2 @ 1000 A, 2.4 @ 833 A.
Current measurement AC 100.1 Hz to 1 kHz Range 40 A / 400 A / 2000 A; 1400 AC RMS.
Resolution 10 mA / 100 mA / 1 A.
Accuracy 10 A: 3.5% rdg + 15 digits
10 A: 3.5% rdg + 5 digits.
Trigger level for Inrush 0.50 A / 5.0 A / 5 A.
Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A.
Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A.
Frequency measurement Measurement range 5.0 Hz to 1 kHz.
Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz).
Accuracy – 5.0 Hz to 100 Hz 0.2% + 2 counts.
Accuracy – 100.1 Hz to 1 kHz 0.5% + 5 counts.
Trigger level Refer to current and voltage tables.
1. Add 2% to error spec for CF > 2
General Specifications
Batteries Six 1.5 V AA NEDA 15 A or IEC LR6.
Battery life (with typical usage, backlight off) 100 hours.
Test leads Rated to 1000 V.
Weight .814 kg (1.8 lb).
Jaw size 58 mm (2.28 in).
Dimensions (L x W x D) 300 x 98 x 52 mm (12 x 3.75 x 2 in).
Safety rating IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III.
Environmental Specifications
Operating temperature 32°F to +122°F (0°C to +50°C).
Storage temperature -4°F to 140°F (-20°C to +60°C).
Operating humidity 0 to 95% (non-condensing).
Operating altitude 2000 m.
Storage altitude 10,000 m.
IP rating 42 (indoor use only).
Drop test requirements 1 m.
EMI, RFI, EMC FCC part 15, IEC/EN 61326-1:1997 class B
IEC/EN 61326:1997 3V/m, performance criteria B, EN61325.
Temperature coefficients Current 0.1% of reading per °C outside 22°C to 24°C.
Voltage 0.1% of reading per °C outside 22°C to 24°C.

Download

Fluke 350 Series Datasheet

PDF Specifications of the Fluke 353 & 355 2000A Clamp Meters.

Download (99.91k)

No customer reviews for the moment.

Write your review

Fluke 353 True-rms 2000 A Clamp Meter
COMPONENT PARTS DESCRIPTION PART No.
TL224 SureGrip Sillicone Rubber Test lead set. 1610198
TP2-1 Test Probes. 3971283
C43 Soft Meter Case. 1663230

16 other products in the same category:

arrow_upward