Chauvin C.A 6505

Chauvin Arnoux authorised distributor and calibration house.

Includes: carrying bag, 2 m safety leads with a HV plug at each end (one red and one blue), 2 m guarded safety lead with a HV plug at one end and a HV plug with a rear pick-up jack at the other end (black), 0.35 m guarded safety lead with a HV plug at one end and a HV plug with a rear pick-up jack at the other end (blue), 3 alligator clips (red, blue and black), 1.80-m mains power lead, user manuals on CD-ROM.

P01139704
£1720.00
£2064 Inc. VAT

The Chauvin C.A 6505 megohmmeter is a portable instrument housed in a rugged field case with lid and operates on either battery or line power. It makes voltage, insulation, and capacitance measurements.

As soon as the switch is set to an insulation measurement position, the instrument automatically measures the presence of any AC/DC voltage. This voltage is measured at all times and indicated on the small display unit. The CA6505 automatically determines AC or DC: the AC measurement is an RMS value.

Insulation is sensitive to temperature and humidity variations. In addition, measurement is affected by the appearance of disturbance currents. To overcome these effects, long-term measurements must be performed and the PI and DAR coefficients must be calculated. They will then allow qualification of the insulants and their ageing.

FEATURES

Automatic voltage measurement,
Automatic detection of the presence of an external AC or DC voltage on the terminals.
Simple user interface,
Calculation of the PI and of the DAR.
Fuse protection of the instrument, with detection of a defective fuse.
Operator safety thanks to the automatic discharging of the device tested.
Automatic power-down of the instrument to extend battery life.
Indication of the battery charge condition.
Large backlit LCD display unit with many announciators for very easy reading.

Chauvin C.A 6505 Specifications
Fixed test voltages 500 V 1000 V 2500 V 5000 V
Insulation ranges 10 kΩ to 2 TΩ 10 kΩ to 4 TΩ 10 kΩ to 10 TΩ 10 kΩ to 10 TΩ
Adjustable test voltage 40 V to 5,100 V in 10 or 100 V increments.
Voltage 1 to 5,100 V (15 Hz to 500 Hz or DC).
Capacitance 0.001 to 49.99 F.
Leakage current measurement 0.00 - 3mA.
Functions
Display Large LCD screen.
Backlighting
Programmable alarms No.
Smoothing of display No.
Prog. test duration
Calculation of ratios DAR - PI.
Step voltage mode
Calc. of R at reference T° No.
Locking of test voltage
R(t) No.
Storage
RS 232
Printing of measurements
PC software
Power supply Rechargeable NiMH battery.
Battery life 30 days with 10 DARs and 5 PIs / day.
Electrical safety IEC 61010-1 (Cat. III 1,000 V or Cat. I 2,500 V) and 61557.
Dimensions (L x W x H) 270 x 250 x 180 mm.
Weight 4.3 kgs.
Chauvin C.A6505 warranty 12 months.

Download

Chauvin 5kV Testers Datasheet

PDF Specifications of the Chauvin CA6545, CA6547, CA6549 & the CA6505 5kV Testers.

Download (708.2k)

No customer reviews for the moment.

Write your review

Chauvin C.A 6505
COMPONENT
DESCRIPTION PART No.
HV Lead Blue HV Croc Lead, Blue 8m. P01295214
HV Lead Red HV Croc Lead, Red 8m. P01295215
HV Lead Black HV Large Croc Lead, Black, rear head pick up. 8m. P01295216
HV Leads HV Large Croc Lead, Blue, Red, Black. P01295220
2x HV Leads Set of 2 HV Simplified Leads. P01295231
Bag Standard Bag. P01298066

12 other products in the same category:

arrow_upward