- Hamilton01698 829711
- Leeds0113 235 1356
- Belfast02890 830302
Fluke 124B/S Hand-Held Oscilloscope
Includes: Fluke 124B Hand-Held Oscilloscope, Shielded Test Leads with Black Ground Leads, Test Lead Black (for Grounding), Hook Clips (red, blue), Banana-to-BNC Adapters (black, x1), 10:1 Voltage Probe, USB Angled Adapter, WiFi USB Adapter, Switch Mode Power Supply, Adapter/Battery Charger, Rechargeable Li-ion Battery Pack, Soft Carrying Case, Magnetic Hanger, FlukeView® ScopeMeter® Software for Windows, Screen Protector.
The Fluke 124B Industrial ScopeMeter Test Tool includes innovative functions designed to help technicians troubleshoot faster and get the answers they need to keep their systems up and running
Display waveforms with Connect and View™ trigger and setup technology and automatically view related numerical measurements using Fluke IntellaSet™ technology, all without making manual measurement adjustments. With Recorder Event Detect capabilities, elusive intermittent events are captured and logged for easy viewing and analysis.
Connect-and-View™
Fluke’s unique Connect-and-View™ triggering technology recognises signal patterns, and automatically sets up the correct triggering to provide a stable, reliable and repeatable display.
Connect-and-View™ triggering is designed to work with virtually any signal, including motor drives and control signals - without adjusting parameters, or even touching a button.
Signal changes are instantly recognised and settings are automatically adjusted, providing a stable display even when measuring multiple test points in quick succession.
IntellaSet™/AutoReading
The Auto Readings function with Fluke IntellaSet™ technology uses proprietary algorithms to intelligently analyse the measured waveform and automatically displays the most appropriate numerical measurements on screen, so you can get the data you need easier than ever before.
FEATURES
Dual-input digital oscilloscope and multimeter.
40 MHz or 20 MHz oscilloscope bandwidth.
Two 5,000-count true-rms digital multimeters.
Connect-and-View™ trigger simplicity for hands-off operation.
IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal.
Dual-input waveform and meter reading recorder for trending data over extended periods.
Recorder Event Detect captures elusive intermittent signals on repetitive waveforms up to 4 kHz.
Shielded test leads for oscilloscope, resistance and continuity measurements.
Resistance, continuity, diode and capacitance meter measurements.
Power measurements (W, VA, VAR, PF, DPF, Hz).
Voltage, current and power harmonics.
Check Industrial networks with BusHealth physical layer tests against defined reference levels.
Save or recall data and instrument setups.
Store instrument setups defined by a test sequence for routine maintenance or most often used test procedures.
External optically isolated USB interface to transfer, archive and analyze scope or meter data.
Rugged design to withstand 3g Vibration, 30g shock, and rated IP51 according to EN/IEC60529.
Highest safety rating in the industry: safety rated for CAT IV 600 V.
Li-Ion rechargeable battery, seven-hours operation (with four-hour charge time).
Product Comparison Chart | Fluke 123B | Fluke 124B | Fluke 125B | ||||||
FUNCTIONS | |||||||||
Full Function Dual Input Scope and Meter | |||||||||
Oscilloscope Bandwidth MHz | 20 | 40 | 40 | ||||||
Meter and Scope Recorder | |||||||||
Scope Cursor Measurements | |||||||||
BusHealth | |||||||||
INCLUDED ACCESSORIES | |||||||||
10:1 voltage probe | |||||||||
i400S AC current clamp |
Dual Input Meter | ||||
The accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C. |
||||
Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe uncertainty +1%. More than one waveform period must be visible on the screen. |
||||
Input A and input B - DC voltage (VDC) | ||||
Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V. | |||
Accuracy | ±(0.5% +5 counts). | |||
Common mode rejection (CMRR) | >100 dB @ dc, >60 dB @ 50, 60, or 400 Hz. | |||
Full scale reading | 5000 counts. | |||
True-rms voltages (V ac and V ac+dc) | ||||
Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V. | |||
Accuracy for 5% to 100% of range (DC coupled) | DC to 60 Hz (V ac+dc) - ±(1% +10 counts) 1 Hz to 60 Hz (V ac) - ±(1% +10 counts). |
|||
Accuracy for 5% to 100% of range (AC or dc coupled) | 60 Hz to 20 kHz - ±(2.5% +15 counts). | |||
DC rejection (only VAC) | >50 dB. | |||
Common mode rejection (CMRR) | >100 dB @ dc >60 dB @ 50, 60, or 400 Hz. |
|||
Full scale reading | 5000 counts, reading is independent of any signal crest factor. | |||
Peak | ||||
Modes | Max peak, Min peak, or pk-to-pk. | |||
Ranges | 500 mV, 5 V, 50 V, 500 V, 2200 V. | |||
Accuracy |
Accuracy Max peak or Min peak: 5% of full scale Accuracy Peak-to-Peak: 10% of full scale. |
|||
Full scale reading | 500 counts. | |||
Frequency (Hz) | ||||
Ranges | 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz. | |||
Frequency range | 15 Hz (1 Hz) to 50 MHz in continuous autoset. | |||
Accuracy @1 Hz to 1 MHz | ±(0.5% +2 counts). | |||
Full scale reading | 10,000 counts. | |||
RPM | ||||
Max reading | 50.00 kRPM. | |||
Accuracy | ±(0.5% +2 counts). | |||
Duty cycle (PULSE) | ||||
Range | 2% to 98%. | |||
Frequency range | 15 Hz (1 Hz) to 30 MHz in continuous autoset. | |||
Pulse width (PULSE) | ||||
Frequency range | 15 Hz (1 Hz) to 30 MHz in continuous autoset. | |||
Full scale reading | 1000 counts. | |||
Amperes (AMP) | ||||
With current clamp | Ranges: Same as V dc, V ac, V ac+dc, or PEAK Scale factors: 0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA. |
|||
Temperature (TEMP) with optional temperature probe | ||||
Range | 200 °C/div (200 °F/div). | |||
Scale factor | 1 mV/°C and 1 mV/°F. | |||
Accuracy | As V dc (add temp. probe uncertainty). | |||
Decibel (dB) | ||||
0 dBV | 1 V. | |||
0 dBm (600 Ω /50 Ω) | 1 mW referenced to 600 Ω or 50 Ω. | |||
dB on | V dc, V ac, or Vac+dc. | |||
Full scale reading | 1000 counts. | |||
Crest factor (CREST) | ||||
Range | 1 to 10. | |||
Full scale reading | 90 Counts. | |||
Phase | ||||
Modes | A to B, B to A. | |||
Range | 0 to 359 degrees. | |||
Resolution | 1 degree. | |||
Miscellaneous | ||||
Display | 5.7-inch color active matrix TFT 640 x 480 pixels. |
|||
Waveform Display | Vertical: 10 div of 40 pixels Horizontal: 12 div of 40 pixels. |
|||
Power | External: Via Power Adapter BC430 Input voltage: 10 V DC to 21 V DC Power consumption: 5 W typical Input connector: 5 mm jack Internal: Via Battery Pack BP290 Battery power: Rechargeable Li-Ion 10.8 V Operating time: 7 hours with 50% backlight brightness Charging time: 4 hours with test tool off, 7 hours with test tool on Allowable ambient temp: 0 to 40 °C (32 to 104 °F) during charging. |
|||
Memory | Internal memory can store 20 data sets (screen waveform and setup). | |||
Interface | Optically isolated: Transfer screen copies (bitmaps), settings and data USB to PC/laptop: OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®.. |
|||
Dimensions | 259 x 132 x 55 mm (10.2 x 5.2 x 2.15 in). | |||
Weight | 1.4 kg (3.2 lb) including battery pack. | |||
Fluke 124B warranty | 3 years. |
No customer reviews for the moment.
COMPONENT |
DESCRIPTION | PART No. | ||
SP120B |
Screen Protector For 120B Series. | 4744414 | ||
SCC120B | Accessory Kit 120B Series. | 4744423 | ||
OC4USB | Fluke OC4USB USB Interface Cable. | 2166266 | ||
Fluke 80i 110s | AC/DC Current Clamp (100A). | 114519 | ||
Fluke i1000s |
AC Current Probe (1000A). | 1568487 | ||
Fluke i1010 | AC/DC Current Clamp (1000A). | 617735 | ||
Fluke i200s | AC Current Clamp (200A). | 664760 | ||
Fluke-i3000s | AC Current Clamp (3000A). | 657202 | ||
Fluke i3000s Flex-24 | AC Current Clamp (3000A), 610 mm (24 in.). | 2584888 | ||
Fluke i3000s Flex-36 | AC Current Clamp (3000A), 915 mm (36 in.). | 2584901 | ||
Fluke i30s | AC/DC Current Clamp (30A). | 2584935 | ||
Fluke i310s | Current Probe (300A). | 2840309 | ||
Fluke i400s | AC Current Clamp (400A). | 2277202 | ||
Fluke i410 | AC/DC Current Clamp (400A). | 617727 |